Setting on SW2 System component Measuring range and description Unit
Unit output Display takes the form of a
capacity code
Unit output: capacity code
CMF80/90: 14
CMF 140/150: 25
CMT100: 14
CMT150: 25
Capacity code
ON
1 2 3 4 5 6
Vaporiser/condenser tempera-
ture sensor of the indoor unit
TH5
-39 – 88
Settings on the outdoor unit
Temperature sensor TH2
-39 – 88
-39 – +88
If the temperature sensor
measures values below 0°C,
the display switches between
the sign and the value.
1s digit:
(Defrosting mode)
0 = Standard
1 = For high humidity
10s digit
(Operating mode)
0 = Heat pump
1 = Cooling unit
(Single/three-phased)
0 = Single-phased
2 = Three-phased
-39 – +88
If the temperature sensor
measures values below 0°C,
the display switches between
the sign and the value.
°C
°C
ON
ON
ON
1
1
1
2
2
2
3
3
3
4
4
4
5
5
5
6
6
6
13