Remko WPM-Smart-Control-Manual for specialists-WKF-120 Bedienungsanleitung

Stöbern Sie online oder laden Sie Bedienungsanleitung nach Hardware Remko WPM-Smart-Control-Manual for specialists-WKF-120 herunter. REMKO WPM-Smart-Control-Manual for specialists-WKF-120 User Manual Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 100
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
Operating manual
Read the instructions prior to performing any task!
REMKO Smart WP MANAGER
Smart Control for WKF 120/180 and WKF 120/180 Duo
Manual for experienced specialists
0094-2014-10 Edition 1, en_GB
Seitenansicht 0
1 2 3 4 5 6 ... 99 100

Inhaltsverzeichnis

Seite 1

Operating manualRead the instructions prior to performing any task!REMKO Smart WP MANAGERSmart Control for WKF 120/180 and WKF 120/180 DuoManual for e

Seite 2

Overview of the menus (User level)LEVEL 03D houseHot water Room climate..LEVEL 1Information SettingsChimneysweep *)LEVEL 2BasicinformationSolarDomesti

Seite 3 - Table of contents

ConsultingThanks to intensive training, our consultants are always completely up-to-date in terms of technical knowledge. This has given us the reputa

Seite 4

"3D house" animationOnce the Smart Control commissioning wizard hasbeen completed, you will see the home screen withthe 3D house. Pressing t

Seite 5

Explanation of operating modes:Standby - the controller waits for the next requestDispensing operation - hot water is being dis-pensedCirculation - ci

Seite 6

Favourites menu: for the userUsing the rotary knob (turning it clockwise) you canaccess other views. They allow you to rapidly andeasily adjust the mo

Seite 7 - Basic settings

One-off hot water / party modeActivating Party mode (select with the rightsoftkey) causes the next window of time withreduced heating to be disregarde

Seite 8

Solar yieldTime periodHistoryFig. 24: Solar yieldsNOTE:These yields are also displayed with an activatedPV functionThen turn the rotary knob clockwise

Seite 9 - Operation - User level

"Main menu" menu itemPressing the Menu key takes you to the main menu. There is an expert mode and a user mode. The twoauthorisation levels

Seite 10 - REMKO Smart WP MANAGER

"Information" menu item - UserThis menu contains information about the current operating status of the system. The menu is opened withthe

Seite 11 - Next viewStart animation

"Information" menu item (continued) - UserAuthorisa-tion levelLevel 2menu itemLevel 3 menu item InfoSolarPump A01You can findmany of the i

Seite 12

"Information" menu item (continued) - UserAuthorisa-tion levelLevel 2 menuitemLevel 3 menu item InfoCoolingCooling cycle set temp.You can

Seite 13

Translation of the original operating manualRead these operating instructions carefully before commis-sioning / using this device!These instructions a

Seite 14

"Information" menu item (continued) - UserAuthorisa-tion levelLevel 2 menuitemLevel 3 menu item InfoHeat pump(I/0 2)Only WKF DuoHeat pump

Seite 15 - Time period

"Information" menu item (continued) - UserAuthorisa-tion levelLevel 2 menuitemLevel 3 menu item InfoMeter read-ingsSolarCurrent outputYou

Seite 16

"Information" menu item (continued) - UserAuthorisa-tion levelLevel 2 menuitemLevel 3 menu item InfoMeter read-ingsPhotovoltaicPhotovoltai

Seite 17

"Settings" menu item - UserIn this menu you can configure the settings. For example, you can adjust hot water and heating tempera-tures or

Seite 18

"Settings" menu item (continued) - UserAuthorisa-tion levelLevel 2 menuitemLevel 3 menu item Level 4 menu item InfoHeating /coolingModeRoo

Seite 19 - Short-term heating offset

"Settings" menu item (continued) - UserAuthorisa-tion levelLevel 2 menuitemLevel 3 menu item Level 4 menu item Info3rd mixedHeating cycle(

Seite 20

4 Operation - Expert level 4.1 General notes regarding themenu structure of the controller The following information is primarily directed at

Seite 21

Overview of the menus (Expert level)LEVEL 03D houseHot water Room climate..LEVEL 1Information SettingsChimneysweep *)LEVEL 2BasicinformationSolarDomes

Seite 22

4.2 Commissioning wizard The commissioning wizard which starts when thecontroller is activated is intended for programmingthe controller for use on

Seite 23

Setting the countrySelect the country with the rotary knob and confirmthe entry with "OK".Fig. 31: Selecting a countryMenu item ParameterFac

Seite 24

Table of contents1 Safety and usage instructions...

Seite 25

Menu item ParameterFac-tory settingPolskiČeštinaPress "Next".Setting the time zone for the winter timeSelecting the time zone for the winter

Seite 26

Software updateWhen first installing the controller this parameter isconfirmed with "NO".If a new software status is installed after the ini

Seite 27 - Error messages

Domestic hot-water heatingOptionally, you can activate or deactivate the"Domestic hot-water heating" function. ActivateDomestic hot-water he

Seite 28

Hot water circulationIf there is a hot water circulation pump in thebuilding, which you are intending to operate in anenergy-saving manner using the c

Seite 29

Impulse-guided circulation -Running time of the circulationSwitch-on time of the circulation pump after a dis-pensing impulse.If the circulation line

Seite 30

Unmixed heating cycleOptionally, you can activate or deactivate the"Unmixed heating cycle" function. Activate the"Unmixed heating cycle

Seite 31

Setting the heating curve:- Activate the base point with the right softkey, setwith the rotary knob and conform with the rightsoftkey.Fig. 49: Settin

Seite 32

Standard inlet temperature:the standard inlet temperature corresponds to theset temperature of the heating water at thestandard outside temperature in

Seite 33

2nd mixed heating cycleActivate if a heating cycle with radiators isinstalled. (select with the rotary knob and confirmwith "OK")Fig. 57: Ac

Seite 34

Fig. 60: Setting the standard inlet temperatureFig. 61: Set the standard outside temperatureFixed-value-control heating cycle modeSpecify the set temp

Seite 35

1 Safety andusage instructions 1.1 General safety notes Carefully read the operating manual before com-missioning the units for the first time.

Seite 36

Standard inlet temperature:the standard inlet temperature corresponds to theset temperature of the heating water at thestandard outside temperature in

Seite 37

4th mixed heating cycle (only WKF Duo)Activate if a heating cycle with radiators isinstalled. (select with the rotary knob and confirmwith "OK&qu

Seite 38

Fig. 70: Setting the standard inlet temperatureFig. 71: Set the standard outside temperatureSystem separationActivation if a mixed heating cycle is se

Seite 39

Setting the building time constantThe building time constant specifies the ability of the building to retain heat. The building constant isdependent u

Seite 40

Cooling functionActivate (select with the rotary knob and confirmwith "OK") if the building is to be actively cooledwith the heat pump in su

Seite 41

Selecting the pump systemSelect the pump system for the speed controlsystem (select with the rotary knob and confirmwith "OK"). The speed co

Seite 42

Medium flow rate probeThe amount of heat delivered from solar yields isrecorded continuously, and can be called up in theform of a daily or cumulative

Seite 43

Heat carrier mediumSelect (select with the rotary knob and confirm with"OK") the type of solar fluid used, in order to calcu-late the amount

Seite 44

Acquisition of the stored energy via the S 09probeIf heating is to be provided from the available solaryield (if required), this parameter must be act

Seite 45

4.3 Template hydraulic diagrams with installation parameters NOTICE!The following template hydraulic systems are only to be used as a planning aid

Seite 46

1.6 Safety notes for the operator The operational safety of the units and compo-nents is only assured providing they are used asintended and in a f

Seite 47

Menu item Parameter Factory setting WKFWKFDuoControl panel address Control panel 1-3 Control panel 1 X XCountry Deutschland - Slovensko Deutschland X

Seite 48

Menu item Parameter Factory setting WKFWKFDuo3rd mixed heating cycle Activated / Deactivated Deactivated - XHeating cycle mode Heating curve Deactivat

Seite 49 - 1 F2 F3 F4

Hydraulic diagram for heat pump assembly WKF FrankfurtFunctions: heating and hot water, operating mode: monoenergetic or bivalent alternative. Solar p

Seite 50

Menu item Parameter Factory setting WKFWKFDuoOperating modeMonoenergetic/bivalent alternativeMonoenergetic X XDom. hot-water heating Activated / Deact

Seite 51

Menu item Parameter Factory setting WKFWKFDuo4th mixed heating cycle Activated / Deactivated Deactivated - XHeating cycle mode Heating curve Deactivat

Seite 52

Hydraulic diagram for heat pump assembly WKF Frankfurt SolarFunctions: heating/hot water and solar, operating mode: monoenergetic or bivalent possible

Seite 53

Menu item Parameter Factory setting WKFWKFDuoActivate heat pump Activated / Deactivated Activated X XOperating modeMonoenergetic/bivalent alternativeM

Seite 54

Menu item Parameter Factory setting WKFWKFDuo4th mixed heating cycle Activated / Deactivated Deactivated - XHeating cycle mode Heating curve Deactivat

Seite 55

4.4 Menu structure of the controller "Information" menu item - ExpertThis menu contains information about the current operating status

Seite 56

"Information" menu item (continued) - ExpertAuthorisa-tion levelLevel 2menu itemLevel 3 menu itemLevel 4 menuitemInfoBasic infor-mation (c

Seite 57

1.11 Transport and packaging The devices are supplied in a sturdy shipping con-tainer or inside the heat pump casing. Pleasecheck the equipment imm

Seite 58

"Information" menu item (continued) - ExpertAuthorisa-tion levelLevel 2 menuitemLevel 3 menu item Info1st unmixedHeating cycleHeating cycl

Seite 59

"Information" menu item (continued) - ExpertAuthorisa-tion levelLevel 2 menuitemLevel 3 menu item InfoCoolingChangeover valve A14You can f

Seite 60

"Information" menu item (continued) - ExpertAuthorisa-tion levelLevel 2 menuitemLevel 3 menu item InfoHeat pumpHeat pump statusYou can fin

Seite 61

"Information" menu item (continued) - ExpertAuthorisa-tion levelLevel 2 menuitemLevel 3 menu item InfoHeat pump(I/0 2)Only WKF DuoHeat pum

Seite 62

"Information" menu item (continued) - ExpertAuthorisa-tion levelLevel 2 menuitemLevel 3 menu item Level 4 menu item InfoMeter read-ingsSol

Seite 63

"Information" menu item (continued) - ExpertAuthorisa-tion levelLevel 2 menuitemLevel 3 menu item Level 4 menu item InfoMeter read-ingsHou

Seite 64

"Information" menu item (continued) - ExpertAuthorisa-tion levelLevel 2 menuitemLevel 3 menu item InfoChecklistCollector temp. S01You can

Seite 65

"Settings" menu item - ExpertIn this menu you can configure the settings. For example, you can adjust hot water and heating tempera-tures

Seite 66

"Settings" menu item (continued) - ExpertAuthorisa-tion levelLevel 2 menuitemLevel 3 menu item Level 4 menu item InfoBasic settings System

Seite 67

"Settings" menu item (continued) - ExpertAuthorisa-tion levelLevel 2 menuitemLevel 3 menu item Level 4 menu item InfoSolarCollectorMax. te

Seite 68

Pressing the Info key (6) delivers information andsupport at any time on the area currently selected.Pressing the Menu key (7) takes you to the mainme

Seite 69

"Settings" menu item (continued) - ExpertAuthorisa-tion levelLevel 2 menuitemLevel 3 menu item Level 4 menu item InfoHot waterDomestic wat

Seite 70

"Settings" menu item (continued) - ExpertAuthorisa-tion levelLevel 2 menuitemLevel 3 menu item Level 4 menu item InfoHeating /coolingBuild

Seite 71

"Settings" menu item (continued) - ExpertAuthorisa-tion levelLevel 2 menuitemLevel 3 menu item InfoSolar heatingExcessive temperature in t

Seite 72

"Settings" menu item (continued) - ExpertAuthorisa-tion levelLevel 2 menuitemLevel 3 menu item Info2nd mixedHeating cycleHeating cycle mod

Seite 73

"Settings" menu item (continued) - ExpertAuthorisa-tion levelLevel 2 menuitemLevel 3 menu item Info4th mixedHeating cycle(I/0 2)Only WKF D

Seite 74

"Settings" menu item (continued) - ExpertAuthorisa-tion levelLevel 2 menuitemLevel 3 menu item Level 4 menu item InfoHeat pumpBasic settin

Seite 75

"Settings" menu item (continued) - ExpertAuthorisa-tion levelLevel 2 menu item Level 3 menu item Level 4 menu item InfoHeat pump cont.Outp

Seite 76

"Settings" menu item output restriction(night mode with noise optimisation)Fig. 90: "Output restriction" menu itemUnder the leve

Seite 77

Fig. 96: Output restriction cooling (reduced)The output restriction in "reduced" cooling mode(22:00 - 06:00 hrs) is set to 90% in the factor

Seite 78

"Chimney sweep" menu item - ExpertAuthorisa-tion levelLevel 2 menu item Level 3 menu item InfoMode Normal operation / test mode You can fi

Seite 79

Language / TimeZurück 1/6OKGrundeinstellungenBasic settingsBackFig. 7: Language / TimeSelecting a parameterPress the rotary knob until you reach the &

Seite 80

"Messages" menu item - ExpertPressing "OK" (right softkey) takes you to submenus of the menu item "Messages".This is w

Seite 81

"Message" menu item (continued) - ExpertManual mode (relay test) (continued) Parameter Selection parameter Pump 2nd mixed heating cycl

Seite 82

"Message" menu item (continued) - ExpertManual mode (relay test) (continued) Parameter Selection parameter Close mixer 2nd mixed heatin

Seite 83

"Message" menu item (continued) - ExpertManual mode (relay test) (continued) Parameter Selection parameter Pump indoor unit (top) Outp

Seite 84

"Message" menu item (continued) - ExpertManual mode (probes) (continued) Parameter Selection parameter 4th mixed heating cycle inlet te

Seite 85

"Message" menu item (continued) - ExpertManual mode (probes) (continued) Parameter Selection parameter Heat generator return temperatu

Seite 86

5 Assembly 5.1 Room installation of theSmart-Control NOTICE!Only use the unit in dry areas and protect itfrom electromagnetic radiation.The Sma

Seite 87 - Electrical wiring

6 Electrical wiring 6.1 Electrical configuration - I/0 module 01 Use wire gauge corresponding with the connection cable supplied!Lay load lines

Seite 88

6.2 Terminal assignment / legend - I/0 module Terminal assignment I/0 module 01Designation Input Output Signal DescriptionPower X Power supply

Seite 89

Designation Input Output Signal DescriptionA11.1 X Changeover valve 2nd WE Smart BVTA12.1 X Not connectedA13.1 X 2nd mixed heating cycle p

Seite 90

3 Operation - User level 3.1 Menu structureof the controller The following information is primarily directed atsystem operators. Specialists ca

Seite 91

6.3 Electrical configuration - I/0 module 02 Use wire gauge corresponding with the connection cable supplied!Lay load lines separately to measuring

Seite 92

6.4 Terminal assignment / legend - I/0 module Terminal assignment I/0 module 02Designation Input Output Signal DescriptionPower X Power supply

Seite 93 - PV power utilisation

Designation Input Output Signal DescriptionA12.2 X Not connectedA13.2 X 4th mixed heating cycle pump (230V) switchedA14.2 X Not connectedA

Seite 94

7 PV power utilisation 7.1 Higher energy consumptionfrom the combination of heatpump and PV plant Ideal for new and existing photovoltaic plants

Seite 95 - Systems with a

7.2 Using the PV power surplus The self-generated photovoltaic power is used inthe first instance for power needs in the home(lighting, household a

Seite 96

7.3 Systems with aphotovoltaic plant SystemsThe smart heating function can be used with thefollowing variants:n Hybrid heat pumpn Split air/water h

Seite 97

8 Index CChanging parameters... 7Connection of the controller to the electricitymeters and inverter...

Seite 99

REMKO Smart WP MANAGER 98

Kommentare zu diesen Handbüchern

Keine Kommentare