User menu
System
This menu contains all the settings which can be adjusted by the user of the system.
Parameter Value range Default OV*) Comments
Language Depends on variant English Set the language for the controller
LCD contrast (-20) - (20) 04 Set the intensity of the display
LCD brightness Off/On On Switch display backlight ON/OFF
LCD status 1 - 5 1
Since the display is the biggest consumer, while it is not
being operated, it switches into a power-saving mode (only
displaying the time and date).
In the interests of saving even more power to increase
battery life, the parameter [LCD Status] will switch off the
display altogether when the controller is in certain states:
1: Display ON
2: Display ON, with heating programme enabled
3: Display ON, if demand exists for heating
4: Display ON/OFF with time interval (10s OFF/ 5s ON)
5: Display OFF
If a control is operated, the display switches back on
automatically.
*) OV = Own values: space to enter you settings for each parameter in the system
Hot water
Parameter Value range Default OV*) Comments
1x hot water Off/On Off
On => The tank is enabled for charging (e.g. for showering
outside hot water time periods).
Charge begins when “Target temperature 1” is fallen below
by the switching hysteresis.
*) for KM1/6/9 and bus code 00/01 only