Seite 1 - Ausgabe GB – M05

REMKO HTK Mobile oil-fired heating centers Ausgabe GB – M05 REMKO - powerful like a bear. Operation Technology Spare Parts

Seite 2

10 Maintenance and Service Regular maintenance and observance of some basic principles are required to ensure a long service life and to keep the uni

Seite 3 - Operating Instructions

11 Cleaning the combustion chamber 1. Unplug unit from the power source. 2. Remove the burner cover 6 after opening the two quick release fasten

Seite 4 - Description of Device

12 Wiring Diagram HTK 100 Legend HTK 100 and HTK 160 S1 = operating switch S2 = external reset button (burner) H1 = cont

Seite 5 - Installation Requirements

13 Wiring Diagram HTK 160 95961F3.11Q3.1AusLüftenHeizenS1241+32K2.21K6.12K3.112 141121222K2.12K2.121222K3.1TW STBTRH1H2S23 21PERTPE L1 L2 L3NX11234NPE

Seite 6 - Waste Gas Pipes

14 5 Exploded View We reserve the right to make changes to dimensions and design in the interest of technical progress. 43 1 44 33 32 45 6 30 10 25 26

Seite 7 - Before Starting

15 Spare Part List When ordering spare parts please indicate ref. no. and machine no. (see model plate)! No. Description Ref.-No. HTK 100 Ref.-No. H

Seite 8 - Unit Shut Down

16 D C B A Initial Operation of the Forced – Air Burner Preparation After loosening the 4 housing bolts, remove the mount-ing base plate of the hous

Seite 9 - Service and Guarantee

17 Secondary air setting (Setting the nozzle stock) Proceed as follows to preset the secondary air: Use the adjusting screw 1 to adjust the nozzle 2 t

Seite 10 - Maintenance and Service

18 Technical Data Model HTK 100 HTK 160 rated heat power max. kW 88 160 rated heat output kW 80 146 rated air output 1) m³/h 6,260 12.780

Seite 11

19 Maintenance Log 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 Clean unit -surface- Clean u

Seite 13 - Wiring Diagram HTK 160

REMKO GmbH & Co. KG Klima- und Wärmetechnik D-32791 Lage • Im Seelenkamp 12 D-32777 Lage • PO Box 1827 Phone +49 (5232) 606 - 0 Fax +49 (5

Seite 14 - Exploded View

3 Mobile oil-fired Heating Centers REMKO HTK Contents Page Safety Instructions

Seite 15 - Spare Part List

4 Safety Instructions Make sure to observe relevant local building and fire protection codes and abide by professional as-sociation regulations when

Seite 16 - Forced – Air Burner

5 Monitoring operation of device All functions of the unit are fully automatic and moni-tored for safety by the safety facility and the automatic burn

Seite 17

6 Information on the Safety Device The device is equipped with a sensor monitoring feature and is resistant to cool down to temperatures of -20°C; bel

Seite 18 - Technical Data

7 Hot Air Distribution The units are equipped with a high-performance axial fan. This fan has been designed to transport the hot air directly and eff

Seite 19 - Maintenance Log

8 G Extension cables may only be used once they are unrolled. Starting Only those persons who have been trained in operation of the unit may be respo

Seite 20 - • PO Box 1827

9 Forced-air burner and power supply 1. Check whether fuel filter is dirty. Replace dirty filters. 2. Check that all shut-off fittings in the o